Stove compatibility

Compatibility depends on the firmware version of the stove's mainboard, not on the model. Each firmware generation speaks its own variant of the protocol, and the bridge finds out by itself which one your stove uses.

By firmware version

The version is shown in the Info menu of the stove screen.

Stove firmwareStatusReadControl
2.30
e.g. INDUO
Supported All values and settings On/off, mode, power, temperature, schedule, frost protection, room sensor calibration. Wood operation is reported state by state, with bridge firmware 4.1 or later. Reported working on one stove so far, an INDUO, in pellet and in split log operation.
2.29
e.g. DOMO, DOMO BACK, PRIMO MULTIAIR, SUMO
Supported All values and settings Everything: on/off, mode, power, temperature, schedule, frost protection, room sensor calibration, MultiAir fans, baking oven (DOMO BACK)
2.28
e.g. LIVO, INDUO II, SONO
Supported All values and settings On/off, mode, power, temperature, schedule, frost protection, room sensor calibration, MultiAir fans
2.26 / 2.27
e.g. INDUO, LIVO
Supported All values and settings On/off, mode, power, temperature, schedule, frost protection, room sensor calibration
2.25
e.g. SUMO
Partial State, temperatures, inputs and settings. Room temperature in whole degrees Mode, manual power, room set point, stop, and the weekly schedule with one time range a day (no switch per day), tried on one stove. Not tried on a stove: starting it, reduced set point, frost protection, comfort power level. Needs bridge firmware 4.9 or later. Please send the diagnostic file if you try it
Older than 2.25 Not supported Not supported, and no support is planned. Have the stove's mainboard updated to 2.25 or later.

Firmware 2.28 needs bridge firmware 4.0 or later for everything: versions before 3.6.1 could show "FIRENET UPDATE" or the code UW29 instead of linking, and versions before 4.0 only sent on/off, mode, power and temperature to the stove.

First start

On its first start with a stove, the bridge tries the three protocol variants in turn and keeps the one the stove answers. This takes about six seconds; afterwards it starts with the right one directly. There is nothing to configure.

MultiAir fans

The MultiAir controls appear on the page when the stove reports one of these models:

ModelMultiAir
ROCO MULTIAIRFans 1 and 2
DOMOFans 1 and 2
PAROFans 1 and 2
SONOFans 1 and 2
CONNECTFans 1 and 2
DOMO BACKFans 1 and 2
SUMO MULTIAIRFans 1 and 2
PRIMO MULTIAIRFans 1 and 2

On any other model, the Stove tab shows a link "My stove has MultiAir: show its settings". Use it if your stove is equipped and not in this list, and tell us so that we add it.

ANIMO numbers its models on its own: on an ANIMO stove, the MultiAir settings appear for the AVITO, PURE and ADUO, which ANIMO sells with MultiAir as an option (bridge firmware 5.1 or later).

ANIMO stoves (Wi-Fire)

ANIMO is the sister brand of RIKA, manufactured by RIKA Innovative Ofentechnik GmbH in Austria. Both brands share the same electronics, the same mainboard firmwares (2.25 to 2.30) and the same serial protocol.

ANIMO sells its stick under the name Wi-Fire (RIKA calls it Firenet). Open Firenet replaces it in the same way, in the same USB socket.

Known ANIMO models:

ModelType
AVITOPellet stove
AVITO SLIMPellet stove (flat)
AVITO RAOPellet stove (top flue outlet)
ADEVOPellet stove
PUREPellet stove
ADUOCombined pellet and log stove
AMITOPellet stove
ARONDOPellet stove (round)
ADUO 2Combined pellet and log stove

The stove reports whether it is branded as RIKA or ANIMO in its diagnostic data (sensor fabNumber: 1 for RIKA, 2 for ANIMO).

The board

The firmware is tested on the ESP32-S3. The board must expose the chip's native USB (USB OTG) on a connector: the stove acts as the USB host and the bridge as a USB serial device.

Tell us about your stove

If your stove or firmware version is not listed, or behaves differently, open an issue with the model, the firmware version, the log (CDC Logs tab) and the output of http://open-firenet.local/api/state.